Lab Mechanical Testing25 Years Experience

NATA accredited company authorised to issue NATA certification

  • Lab Mechanical Testing
  • Our Accreditation Details
  • Standards We Test To

nata smallIt is of paramount importance that mechanical testing of contamination control equipment is undertaken by a highly experienced, NATA accredited company authorised to issue endorsed NATA certification.

For over 24 years, Independent Air Flow Services have been successfully providing testing and accreditation services, and are fully NATA (Testing Authority Australia) accredited testing laboratory for Controlled Environments.

Our technicians have a significant knowledge of all types of Clean Rooms, Biological Safety Cabinets, Clean Work Stations, Pharmaceutical Isolators, HEPA Filter Installations and Fume Hoods.

(Q.A. Accredited to ISO/IEC 17025, Accreditation Number: 3098)

NATA Accreditation No. 3098Independent Air Flow Services Pty Ltd   |   ABN: 55 066 984 610
Accredited by the National Association of Testing Authorities

Accreditation No: 3098

Independent Air Flow Services complies with the requirements of ISO/IEC 17025:2005

13.69 Controlled environments by the methods of -

AS 1807.1; 1807.3; 1807.5; 1807.6; 1807.7; 1807.8; 1807.10;
1807.15; 1807.16; 1807.20; 1807.21; 1807.22; 1807.23 ; 1807.24; 1807.25, 1807.26
AS/NZS 2243.8 Appendix A & B and AS/NZS 2243.9 Appendix A & B
AS/NZS ISO 14644.1 Annex B NSF/ANSI 49 Annex F Methods F3, 4, 5, 9,10 and 11

.01 Clean rooms and workstations
.02 Biological safety cabinets
.03 Fume cupboards

Independent Air Flow Services is NATA accredited to perform the following tests, all of which involve current certificated calibration equipment and / or instruments in accordance with NATA accreditation requirements.

  • AS1807.1 Determination of air velocity and uniformity of air velocity in clean workstations, laminar flow safety cabinets and pharmaceutical isolators.
  • AS1807.3 Determination of air velocity and uniformity of air velocity in laminar flow clean rooms.
  • AS1807.5 Determination of work zone integrity.
  • AS1807.6 Determination of integrity of terminally mounted HEPA filter installations.
  • AS1807.7 Integrity of HEPA filter systems not terminally mounted.
  • AS1807.8 Particle counting in work zone by automatic particle counter.
  • AS1807.10 Determination of air pressure of clean rooms and pharmaceutical isolators
  • AS1807.12 Determination of Temperature in work zones
  • AS1807.13 Determination of relative Humidity in clean rooms
  • AS1807.15 Determination of luminance.
  • AS1807.16 Determination of sound level in clean rooms.
  • AS1807.20 Determination of sound level at installed workstations, safety cabinets and pharmaceutical isolators.
  • AS1807.21 Determination of inward air velocity of Class I biological safety cabinets.
  • AS1807.22 Determination of air barrier containment of laminar flow safety cabinets.
  • AS1807.23 Determination of intensity of radiation from germicidal ultraviolet lamps.
  • AS1807.24 Determination of recovery times of clean rooms.
  • AS1807.26 Determination of air barrier containment of laminar flow safety cabinets – potassium iodide test.
  • AS/NZS ISO 14644.1:2002 Classification and air cleanliness
  • NSF/ANSI 49 Annex F.2 Down flow velocity
  • NSF/ANSI 49 Annex F.3 Inflow velocity (face velocity)
  • NSF/ANSI 49 Annex F.4 Air flow smoke pattern test
  • NSF/ANSI 49 Annex F.5 HEPA filter leak test
  • NSF/ANSI 49 Annex F.9 Lighting Intensity
  • NSF/ANSI 49 Annex F.11 Noise level test
  • AS/NZS2243.8 Appendix A, Method for determining face velocity of fume cabinets.
  • AS/NZS2243.8 Appendix B, Method for conducting a smoke test for fume cabinets.
  • AS/NZS2243.9 Appendix A, Method for determining face velocity for recirculating fume cabinets.
  • AS/NZS2243.9 Appendix B, Method for conducting a smoke test for recirculating fume cabinets.
  • AS1349-1986 Bourdon tube pressure and vacuum gauge

Scope of accreditation can be verified with NATA website: www.nata.com.au

Independent Air Flow Services

A: PO Box 4469, North Rocks, NSW, 2151
T: (02) 9638 1130
M: 0488 400 072

Accredited by:
The National Association of Testing Authorities

nata small

 

Accreditation No: 3098