Accreditation Details

Independent Air Flow Services has achieved and maintains an extensive range of accreditation credentials, enabling us to offer a wide range of compliance and certification services.

Independent Air Flow Services Pty Ltd   |   ABN: 55 066 984 610
Accredited by the National Association of Testing Authorities – Accreditation No: 3098

Independent Air Flow Services complies with the requirements of ISO/IEC 17025

13.69 Controlled environments by the methods of:

.01 Clean rooms and workstations

.02 Biological safety cabinets

.03 Fume cupboards

Standards

Independent Air Flow Services is NATA accredited to perform the following tests, all of which involve current certificated calibration equipment and / or instruments in accordance with NATA accreditation requirements.

  • AS1807.1 Determination of air velocity and uniformity of air velocity in clean workstations, laminar flow safety cabinets and pharmaceutical isolators.
  • AS1807.3 Determination of air velocity and uniformity of air velocity in laminar flow clean rooms.
  • AS1807.5 Determination of work zone integrity.
  • AS1807.6 Determination of integrity of terminally mounted HEPA filter installations.
  • AS1807.7 Integrity of HEPA filter systems not terminally mounted.
  • AS1807.8 Particle counting in work zone by automatic particle counter.
  • AS1807.10 Determination of air pressure of clean rooms and pharmaceutical isolators
  • AS1807.12 Determination of Temperature in work zones
  • AS1807.13 Determination of relative Humidity in clean rooms
  • AS1807.15 Determination of luminance.
  • AS1807.16 Determination of sound level in clean rooms.
  • AS1807.20 Determination of sound level at installed workstations, safety cabinets and pharmaceutical isolators.
  • AS1807.21 Determination of inward air velocity of Class I biological safety cabinets.
  • AS1807.22 Determination of air barrier containment of laminar flow safety cabinets.
  • AS1807.23 Determination of intensity of radiation from germicidal ultraviolet lamps.
  • AS1807.24 Determination of recovery times of clean rooms.
  • AS1807.26 Determination of air barrier containment of laminar flow safety cabinets – potassium iodide test.
  • AS ISO 14644.1:2017 Classification and air cleanliness
  • NSF/ANSI 49 Annex F.2 Down flow velocity
  • NSF/ANSI 49 Annex F.3 Inflow velocity (face velocity)
  • NSF/ANSI 49 Annex F.4 Air flow smoke pattern test
  • NSF/ANSI 49 Annex F.5 HEPA filter leak test
  • NSF/ANSI 49 Annex F.9 Lighting Intensity
  • NSF/ANSI 49 Annex F.11 Noise level test

For further details about NATA accreditation and Independent Air Flow’s accreditation status please refer to the below links: